MS 1910 Compliant - ubbl certified - klang valley
Fire Sprinkler System for Factories & Warehouses in Klang Valley & Selangor
FireVant designs and installs automatic fire sprinkler systems for industrial and commercial buildings across Klang Valley and Selangor.
Wet pipe and dry pipe configurations, certified sprinkler heads, full system design and installation — one contractor, built to Malaysian fire safety standards.

Is a Fire Sprinkler System Mandatory for Your Building?
Yes — and most factory owners underestimate how broadly Malaysian fire safety regulations apply. Under UBBL Malaysia and the Fire Services Act 1988, automatic fire sprinkler systems are required for most commercial and industrial buildings above certain floor areas and risk classifications.
An automatic fire sprinkler system is the most effective passive suppression layer in any building — activating only at the sprinkler head nearest to the heat source, containing fires before they spread beyond the point of origin. Unlike fire alarm systems that alert occupants, sprinkler systems actively suppress the fire.
UBBL MALAYSIA
Mandatory by building classification
UBBL Malaysia requires automatic fire sprinkler systems for factories, warehouses and commercial buildings above specific floor areas and risk categories. A Certificate of Fitness (CF) and annual fire certificate will not be issued without a compliant, installed and commissioned sprinkler system.
Warning: No CF = cannot legally operate.
FIRE SERVICES ACT 1988
Annual fire certificate inspection
Your sprinkler system must be flow-tested, pressure-checked and alarm-tested annually as part of fire certificate renewal. Local authority inspectors verify valve operation, sprinkler head condition, water supply and pump performance. FireVant's annual maintenance contract keeps your certificate valid.
Warning: FC lapse fine: up to RM50,000 or 5 years imprisonment.
MS 1910 & MS 1347
Malaysian standards compliance
Sprinkler system design in Malaysia must comply with MS 1910 — the Malaysian Standard for automatic fire sprinkler systems. Sprinkler heads must carry valid product certification. FireVant designs and installs to MS 1489 standards with fully certified components across every installation.
Warning: Non-compliant design = rejected fire certificate.
Most common · factories, offices, warehouses
Wet Pipe Sprinkler System
The most widely installed fire sprinkler system in Malaysia. Pipework is permanently filled with pressurised water — when a sprinkler head activates from heat, water discharges immediately at the point of fire. Simple, reliable and fast-responding.
Best for:
- ✓ Factories and production floors
- ✓ Warehouses and logistics centres
- ✓ Commercial offices and retail
- ✓ Any environment above 4°C
FireVant recommended for most Klang Valley factories & warehouses
Wet Pipe vs Dry Pipe —
Which Sprinkler System Is Right for You?
FireVant installs both main types of automatic fire sprinkler systems used in Malaysian industrial and commercial buildings. The right choice depends on your building environment, risk classification and local authority requirements.
Cold storage, car parks, unheated spaces
Dry Pipe Sprinkler System
Pipework is filled with pressurised air or nitrogen instead of water. When a sprinkler head activates, the air releases, allowing water to flow to the activated head. Used in environments where water in pipes would freeze or where pre-discharge air provides operational advantages.
Best for:
- ✓ Cold storage and refrigerated warehouses
- ✓ Unheated car parks and loading bays
- ✓ Covered outdoor areas
- ✓ Any space where pipe freezing is a risk
OUR SERVICES
Design, Supply & Install —
One Contractor, Complete System
FireVant handles every stage of your fire sprinkler system — from site-specific design through to installation, commissioning and annual servicing. No handoffs, no coordination gaps, no surprises at inspection time.

System design
We design your sprinkler layout specific to your building — sprinkler head positioning, pipe sizing, zone configuration and water supply requirements to MS 1910 standards. Every layout designed around your actual floor plan and risk classification, not a copied template.

Certified component supply
Sprinkler heads, control valves, alarm check valves, flow switches, pressure gauges and pipework — all supplied with valid product certifications. Full documentation provided for your fire certificate inspection file.

Installation & maintenance
Complete installation by our licensed team. Full commissioning including water flow test, alarm test and pressure verification at every zone before handover. Annual maintenance contracts for fire certificate renewal across Klang Valley and Selangor.
MALAYSIAN BOMBA CERTIFIED • NFPA 13 COMPLIANT • UBBL 1984 ADHERENCE • UL LISTED EQUIPMENT • MALAYSIAN BOMBA CERTIFIED • NFPA 13 COMPLIANT • UBBL 1984 ADHERENCE • UL LISTED EQUIPMENT •